no. |
item |
test condition |
requirements |
9 |
thermal
shock |
solder a test sample to printed
circuit board, and conduct 5 cycles of test under
the conditions shown as below.
0603 & 1005 operating temp. range: -55~125°c
1608 operating temp. range: -40~85°c
cycle:
maximum operating temp. /(30 /-3min)
minimum operating temp. /(30 /-3min) |
no visible damage.
inductance variation within 10%.
q variation within 20%. |
10 |
high humidity
state life test |
keep a test sample in an atmosphere
with a temperature of 40 /-2°c, 90~95%rh for
500 /-12 hours. after the removal from test chamber,
2 to 3 hour of recovery under standard condition,
and measurement shall be made after 24 /-2 hrs of
recover under standard condition. |
no visible damage.
inductance variation within 10%.
q variation within 20%. |
11 |
high humidity
load life test |
solder a test sample to printed
circuit board then keep the test sample in an atmosphere
with a temperature of 40 /-2°c, 90~95%rh for
500 /-12 hours while supplying the rated current.
after the removal from test chamber, 2 to 3 hours
of recovery under standard condition, and measurement
shall be made after 24 /-2 hrs of recovery under
standard condition. |
no visible damage.
inductance variation within 10%.
q variation within 20%. |
12 |
high temperature
state life test |
keep a test sample in an atmosphere
with a temperature of 85 /-2°c for 500 /-12
hours. after the removal from test chamber, 2 to
3 hours of recovery under standard condition, and
measurement shall be made after 24 /-2 hrs of recovery
under standard condition. |
no visible damage.
inductance variation within 10%.
q variation within 20%. |
13 |
high temperature
load |
solder a test sample to printed
circuit board then keep the test sample in an atmosphere
with a temperature of 85 /-2°c for 500 /-12
hours while supplying the rated current. after the
removal from test chamber, 2 to 3 hours of recovery
under standard condition, and measurement shall
be made after 24 /-2 hrs of recovery under standard
condition. |
no visible damage.
inductance variation within 10%.
q variation within 20%. |